Thứ Năm, 26 tháng 9, 2013

AUT8500 Series - Alia Vietnam - New

Công ty TNHH kỹ thuật công nghệ và dịch vụ Tiên Phong
D5 KDC Miễu Nổi, Đinh Tiên Hoàng, P3, Q.Bình Thạnh
Tell : 0915.980.479
        0162.999.888.7
AUT8500 Series

AUT8500 series is an intelligent handheld product, which provides quick and precise measurement of thickness for most industrial material.
AUT8500 series is widely used in various precise measurement for different hardware/parts in industrial realm and diffusely applied in manufacture fields, metal processing or commercial inspection.
FEATURES
 
SPECIFICATION

Model:Model:
AUT8500AAUT8500B
Measuring Range:Measuring Range:
1.2  ~ 225.0 mm1.00 ~ 300.0 mm (1/25" ~ 12")
ResolutionResolution
0.1mm0.01mm
Min. limit for tube:Min. limit for steel tube:
20 * 3.0 mm (f10 Transducer)15 * 2.0 mm (6 Transducer)
Accuracy:20 * 3.0 mm (10 Transducer)
+/-1% of Reading +/-0.1mmAccuracy:
Engineer unit:+/-0.8% of Reading +/-0.05mm
mmEngineer unit:
Sound Velocity Range:mm / Inch
1000 ~ 9999 m/sSound Velocity Range:
Accuracy of Velocity:1000 ~ 9999 m/s
+/-1% of Reading ( Thickness < 20mm )Accuracy of Velocity:
+/-5% of Reading ( Thickness > 20mm )+/-1% of Reading ( Thickness < 20mm )
Operating Temp.:+/-5% of Reading ( Thickness > 20mm )
-20 to +60 oCAlarm Setting:
Battery life:High / Low Thickness Alarm With Buzzer
15 to 20 HoursOperating Temp.:
Power Supply:-20 to +60 oC
1.5V AAA Battery * 3 pcsBattery life:
Power Consumption:30 to 35 hours
<0.54 W (with back light on)Power Supply:
Standard Package:1.5V AAA Battery * 3 pcs
Ultrasonic Thickness GaugePower Consumption:
10 Transducer ( 5MHz )<0.16W (with back light on)
Ultrasonic CouplantStandard Package:
Sample BlockUltrasonic Thickness Gauge
Leather Case Cover10 Transducer ( 5MHz )
Carrying Case6 Transducer ( 5MHz )
Ultrasonic Couplant
Sample Block
Leather Case Cover
Carrying Case

Thứ Tư, 11 tháng 9, 2013

LA 3560 Ono Sokki | Thiết bị đo tiếng ồn hãng Onosokki Vietnam

Công ty TNHH kỹ thuật công nghệ và dịch vụ Tiên Phong
D5 KDC Miễu Nổi, Đinh Tiên Hoàng, P3, Q.Bình Thạnh
Tell : 0915.980.479
        0162.999.888.7
Product Index
Overview of sound measurement
ONO SOKKI Technical Report
Product Brochures (PDF)
Outer Dimension (PDF)


Product Photo(LA-3000 series)
These sound level meters were designed with an emphasis on “measuring while listening to sound” in addition to the original features of measurement and calculation. By adding various options, the LA-3000 can be upgraded to an analyzer, a recorder, and a comparator, performing more than just a sound level meter.
You can check the proper recording of data and the condition of the object via headphones, and see the analysis waveform on the large easy-to-see screen in order to carry out reliable measurement confidently at a site that does not permit any failure. 
Measurement, recording, analysis, and checking can be performed by a single item of equipment, thereby improving the measurement efficiency substantially. 

For more detailed analysis, analysis software made by Ono Sokki is useful such as waveform analysis, sound quality evaluation, or fluctuation sound analysis.

LA-3570 Class 1 (high sensitivity type)Suitable for measuring small sounds in a sound insulating box or similar environment etc.
LA-3560 Class 1 (wide band type)Suitable for making measurements across the entire audible range
LA-3260 Class 2Suitable for measuring environmental noise up to 8 kHz
Features
  • 3.5-inch large easy-to-see screen
  • Direct keys for easy operation
  • Wide linearity range of 110 dB, no need of range switching
  • Quad-channel screen (Up to four different sound level calculation results can be displayed simultaneously.)
  • Enables to measure while listening, and record the sound under measurement
  • Adding options can upgrade the models into higher performance device to serve as an analyzer, a recorder, and a sound comparator. Measurement, recording, analysis and judgment all with the same device
  • Conforms to IEC 61672-1, JIS C1509-1

Illustration (Measurement screen formats(example), Easy display selection, Two outputs possible at a time, Auto memory)
 
Illustration (LA-3000 series Rear panel)
Specification
LA-3570LA-3560LA-3260
Applying standardIEC 61672-1: 2002 Class 1
JIS C 1509-1: 2005 Class 1
IEC 61672-1: 2002 Class 2
JIS C 1509-1: 2005 Class 2
Measurement range (IEC, JIS)A:22 to 130 dB
C:28 to 130 dB
Z:36 to 130 dB
A:27 to 140 dB
C:32 to 140 dB
Z:38 to 140 dB
A:26 to 140 dB
C:30 to 140 dB
Z:36 to 140 dB
Intrinsic noiseA:14 dB or less
C:20 dB or less
Z:28 dB or less
A:19 dB or less
C:24 dB or less
Z:30 dB or less
A:20 dB or less
C:24 dB or less
Z:30 dB or less
Frequency range (IEC, JIS)10 Hz to 15 kHz10 Hz to 20.0 kHz10 Hz to 8.0 kHz
MicrophoneMI-1211
1/2-inch bias type
MI-1235 
1/2-inch electret type
MI-1433 
1/2-inch electret type
Sensitivity level
(re. 1 V/Pa)
-20 dB ± 1.5 dB-29 dB ± 3 dB-29 dB ± 3 dB
Microphone preamplifierMI-3310MI-3230
Linearity rangeWide range: 110 dB / Normal range: 80 dB
Level range7 r