Thứ Ba, 22 tháng 10, 2013

AMC2100 Series, AMC2100-AC-CP-HT-PT, Alia Vietnam

Công ty TNHH kỹ thuật công nghệ và dịch vụ Tiên Phong

D5 KDC Miếu Nổi, Đinh Tiên Hoàng, P3, Q.Bình Thạnh
Contacs: Mai Văn Vinh
Tell : 0915.980.479        0162.999.888.7

Email :      vinhmv@pitesco.com
Website:   www.pitesvietnam.com                                       
                 www.sensor-encoder.com                   
                 www.facebook.com/khotudonghoa


Products // Electromagnetic Flowmeter 
AMC2100 Series

The Aliamag AMC2100 series converter is a microprocessor based intelligent transmitter that can be paired with any of the Alia AMF series sensors. The unit features multiple display parameters including flow rate, flow total, diagnostics, programming and troubleshooting.
FEATURES

 Three line LCD display Flow Rate / Totalizer  Accuracy of +/-0.4% value of reading  Bi-directional flow measurement, current and pulse output  Large digital display  Records up to 99 power on/off time  MODBUS/HART communication
 
SPECIFICATION

Excitation:Keyboard:
DC pulsed3 external keys for programming 
Display:and display control
3 lines LCD with illuminationLow Flow Cutoff:
Line 10 to 9.9 %
11 digit totalizer for forward flowData logger Function:
11 digit totalizer for reverse flow99 times flowrate records for power on/off
11 digit totalizer for differenceRecord Data:
Line 2Date/Time when Power on/off
5 digit flowrate / velocity / % / mA / HZFlow rate when Power on/off
Line 3Totalizer when Power on/off
Parameter / Query / Clr tot / Query LOGDamping:
Alarm, Guidance0 to 99 Seconds
UnitDensity Setting:
M3/H, L/H, Kg/H, T/H, L/min, M3/min, GPH0.1 to 9.99 g/cm3
GPM, ML/H, ML/m, ML/secSelf Diagnosis:
Measuring Range:The following error message are 
Min.  0 to 0.15 m/sdisplayed if failure occurs
Max. 0 to 15 m/s- Coil failure
Accuracy:- Power failure
+/-0.4% read-out values (Velocity >=0.5 m/s)- Overranged output
+/-0.002 m/s (Velocity < 0.5 m/s)- Internal error
Repeatability:- Overflow
+/-0.1% read-out values- Empty pipe
Current Output:Cable Entry:
4-20 mA (Isolated)Standard :PG11 Option:1/2"NPTF
LoadProtection Class:
Max. 600 IP 65
Pulse output:Ambient Temperature:
Open collector
-25 to +65 oC
RatingMaterial:
3 to 30 VDC, 20 mA Max. Aluminum Alloy
Pulse Rate:Power Supply:
1)Scale pulse (Pusle/M3, Pulse/L, Other)90-260 VAC, 50/60 Hz
2)Frequency: 0-5000 Hz24VDC +/-10% (Option)
Pulse Width:Power Consumption:
50% of band width3-17 W (Dependent on sensor size)
Alarm:Weight:
High/Low with open collector output1.4 Kg
RatingMounting:
3 to 30 VDC, 20 mA Max. Wall mounting
Communication:Bracket on 2" pipe
RS 485 (MODBUS Protocol)
HART signal (Compatible)
Data Storage:
Operation parameters and totalizer
figures are stored by EEPROM for more
than 10 years

Thứ Tư, 2 tháng 10, 2013

ATF80 Series | Alia Vietnam | Smart target flowmeter

Công ty TNHH kỹ thuật công nghệ và dịch vụ Tiên Phong
D5 KDC Miễu Nổi, Đinh Tiên Hoàng, P3, Q.Bình Thạnh
Tell : 0915.980.479
        0162.999.888.7
Products // Smart Target Flowmeter 
ATF80 Series

The Alia ATF80 Smart Target Flowmeters revolutionizes the target deflection method of measuring flow. The target displacement is precisely measured by capacitance sensors. The resultant signal is then digitally processed via surface-mount, industrial signal processing to Produce a 4-20mA output proportional to the volumetric flow rate.
Smart Target Flowmeter are suitable for low-velocity & high-temp. gas, steam flowrate. Re-ranging the meter is as simple as changing the target. There is no need to change the whole meter.
FEATURES

 Measure low velocity less than 0.1 m/s
 Measure high-temp., low-press. and low-velocity flare gas.
 4-20 mA output Hart communication
 Low Pressure drop
 The Max. temperature can be up to 450 ¡ãC
 Online calibration by Alia unique software
 Insertion Type or Hot-Tap Type available for large pipeline


 
SPECIFICATION

Size:Local Display:
15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 4 lines LCD (with backlight)
150, 200, 250, 300¡­¡­6000(mm)5 digit flowrate
Measuring Range:8 digit Totalizer
Steam: 0.002 ~ 3400000  Ton/HrCurrent Output:
Gas: 1 ~ 3280000  NM3/Hr4-20 mA 2 wire 
Liquid:0.1 ~ 55800 M3/HrLoad
Material:Rohm=(Vdc-10)*50
Stainless Steel  304 / 316 Alarm Function:
Accuracy:High / Low Alarm
Wafer / Flange TypeTurndown Ratio:
+/-0.75% of reading15:1
Insertion TypeCommunication:
+/-1.6% of readingHart signal
Repeatability:Data Storage:
+/-0.05%FSOperation parameters and totalizer
Multi Flow Range :figures are stored by EEPROM for more
1- 3 flow rangethan 10 years
Process Connection:Housing Material:
Flange / Wafer / InsertionAluminum Alloy
Flanges Type:Cable Entry:
JIS 10K / JIS 20K / JIS 40KStandard :M20  Option:1/2"NPTF
ANSI 150# / ANSI 300# / ANSI 600#Power Supply:
PN 10 / PN 16 / PN25 / PN 4010-32 VDC
Ambient Temperature:Power Effect:
-25 to +70 oC<=0.01% / V
Temperature Effect:Keyboard:
<=+/-1% per 50 oC3 internal keys for programming
Max. Pressure:and display control
100 BarLow Flow Cutoff:
Working Temperature:0 to 20%
Flange / WaferDamping:
-60 to 450 oC0 to 32 seconds
InsertionProtection Class:
-60 to 450 oCIP 67
Hot Tap (Retractable)Explosion Proof, Exd IIC T6
-20 to 80 oCIntrinsically Safe, E ex ia IIC T4