Thứ Tư, 2 tháng 10, 2013

ATF80 Series | Alia Vietnam | Smart target flowmeter

Công ty TNHH kỹ thuật công nghệ và dịch vụ Tiên Phong
D5 KDC Miễu Nổi, Đinh Tiên Hoàng, P3, Q.Bình Thạnh
Tell : 0915.980.479
        0162.999.888.7
Products // Smart Target Flowmeter 
ATF80 Series

The Alia ATF80 Smart Target Flowmeters revolutionizes the target deflection method of measuring flow. The target displacement is precisely measured by capacitance sensors. The resultant signal is then digitally processed via surface-mount, industrial signal processing to Produce a 4-20mA output proportional to the volumetric flow rate.
Smart Target Flowmeter are suitable for low-velocity & high-temp. gas, steam flowrate. Re-ranging the meter is as simple as changing the target. There is no need to change the whole meter.
FEATURES

 Measure low velocity less than 0.1 m/s
 Measure high-temp., low-press. and low-velocity flare gas.
 4-20 mA output Hart communication
 Low Pressure drop
 The Max. temperature can be up to 450 ¡ãC
 Online calibration by Alia unique software
 Insertion Type or Hot-Tap Type available for large pipeline


 
SPECIFICATION

Size:Local Display:
15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 4 lines LCD (with backlight)
150, 200, 250, 300¡­¡­6000(mm)5 digit flowrate
Measuring Range:8 digit Totalizer
Steam: 0.002 ~ 3400000  Ton/HrCurrent Output:
Gas: 1 ~ 3280000  NM3/Hr4-20 mA 2 wire 
Liquid:0.1 ~ 55800 M3/HrLoad
Material:Rohm=(Vdc-10)*50
Stainless Steel  304 / 316 Alarm Function:
Accuracy:High / Low Alarm
Wafer / Flange TypeTurndown Ratio:
+/-0.75% of reading15:1
Insertion TypeCommunication:
+/-1.6% of readingHart signal
Repeatability:Data Storage:
+/-0.05%FSOperation parameters and totalizer
Multi Flow Range :figures are stored by EEPROM for more
1- 3 flow rangethan 10 years
Process Connection:Housing Material:
Flange / Wafer / InsertionAluminum Alloy
Flanges Type:Cable Entry:
JIS 10K / JIS 20K / JIS 40KStandard :M20  Option:1/2"NPTF
ANSI 150# / ANSI 300# / ANSI 600#Power Supply:
PN 10 / PN 16 / PN25 / PN 4010-32 VDC
Ambient Temperature:Power Effect:
-25 to +70 oC<=0.01% / V
Temperature Effect:Keyboard:
<=+/-1% per 50 oC3 internal keys for programming
Max. Pressure:and display control
100 BarLow Flow Cutoff:
Working Temperature:0 to 20%
Flange / WaferDamping:
-60 to 450 oC0 to 32 seconds
InsertionProtection Class:
-60 to 450 oCIP 67
Hot Tap (Retractable)Explosion Proof, Exd IIC T6
-20 to 80 oCIntrinsically Safe, E ex ia IIC T4

Không có nhận xét nào: